US avg 17.3¢/kWh Lowest North Dakota 11.9¢ Highest Hawaii 40.2¢ Gasoline $3.95/gal Data: EIA · AAA
kWhtally
Appliances

How Many Watts Does a Refrigerator Use to Start? Worked Math

On this page
  1. Running watts vs. starting watts
  2. Find your fridge's actual numbers
  3. Worked example: monthly cost and surge
  4. Sizing an inverter or generator for the surge
  5. Running a fridge from a power station
  6. Frequently asked questions

A refrigerator draws roughly 100 to 200 watts while its compressor runs, as a rough rule of thumb. When the compressor starts, it can briefly pull 3 to 6 times that running figure. Use the running watts to estimate electricity cost, and use the starting (surge) watts to choose an inverter, power station, or generator that can start the fridge.

Appliance Energy Cost CalculatorCost per hour, day, month and year for anything you plug in.

Running watts vs. starting watts

Running watts is the steady power a fridge draws while its compressor motor turns. Starting watts, also called surge or inrush, is the spike that occurs for a fraction of a second as the motor begins to spin. The motor must overcome the pressure in the sealed refrigerant system before it reaches normal speed, and that takes a burst of extra current.

A compressor fridge cycles on and off. The running figure applies only while the motor is on, and the starting spike happens each time the compressor restarts. For a fridge that cycles several times an hour, the spike is brief and occurs often, so it matters for equipment sizing but adds little to the bill.

Find your fridge's actual numbers

Check the nameplate label. It is usually on the inside wall, a side panel, or the back of the unit. Many labels list amps and volts instead of watts. Multiply them to get running watts: 1.0 A × 120 V = 120 W.

The rest of this article uses 120 W as an illustrative running figure, not a measurement of any specific model. Replace it with your label's number and the math below will update in the same way. For monthly cost by model type and size, see our refrigerator monthly electricity guide.

Worked example: monthly cost and surge

The assumptions are: 120 W running, a 40% duty cycle (the share of time the compressor runs, the value our calculator uses), a US average residential price of 17.3 cents per kWh from EIA Electric Power Monthly Table 5.6.A (November 2025, preliminary), and 30 days per month.

QuantityValueHow it is computed
Running watts120 WAssumed
Starting watts at 3×360 W120 × 3
Starting watts at 6×720 W120 × 6
Energy per day1.15 kWh120 W × 24 h × 0.40 = 1,152 Wh
Energy per month34.6 kWh1.152 kWh × 30
Cost per day$0.201.152 kWh × $0.173
Cost per month$5.9834.56 kWh × $0.173
Share of 863 kWh typical home4.0%34.56 ÷ 863

At these numbers, the fridge uses about 4% of the energy in a typical US home. The starting spike does not change that total. It changes which equipment can run the fridge.

Sizing an inverter or generator for the surge

Two ratings matter for backup power. The continuous rating must exceed the running watts. The surge rating must exceed the starting watts. For the example fridge:

  • Continuous: at least 120 W, and more with a margin for other loads.
  • Surge: at least 360 W at the 3× figure, and 720 W if the compressor reaches 6×.

If you do not know the real surge figure, design for 720 W. Many inverters and generators list a surge rating separately from the continuous rating, so check that number specifically. If the unit beeps, shuts down, or trips its overload protection when the fridge starts, the surge rating is the likely cause. To size a whole backup setup, use the Backup Power Size Calculator.

Generator safety matters here. Run a gasoline generator outdoors, at least 20 feet from doors, windows, and vents. Never run one in a garage, even with the door open, because carbon monoxide builds up quickly. Install a battery-powered CO alarm inside the home. Plug the fridge into the generator directly or through a properly installed transfer switch. Never connect a generator to a home circuit by backfeeding it through a wall outlet, because that can energize utility lines and injure line workers.

Running a fridge from a power station

A portable power station is quieter and easier to run indoors than a generator, but its battery must cover both the average load and the surge. The average load is the number that drives runtime. This example uses the Power Station Runtime Calculator assumptions: 95% usable capacity for LiFePO4, 88% inverter efficiency, and about 12 W of idle draw.

For a 1,000 Wh power station:

  1. Usable energy: 1,000 Wh × 0.95 = 950 Wh
  2. Average fridge load: 120 W × 0.40 = 48 W
  3. Battery draw for that load: 48 W ÷ 0.88 = 54.5 W
  4. Add idle draw: 54.5 W + 12 W = 66.5 W
  5. Runtime: 950 Wh ÷ 66.5 W = about 14.3 hours

The surge is not in that average. The power station's inverter must still deliver the surge when the compressor starts, so check its surge rating as well. Real runtime also changes with room temperature, how often the door opens, and how full the fridge is. For food safety, the USDA advises that an unopened refrigerator keeps food cold enough for about 4 hours during a power outage, so keep the door closed and plan for that window.

Frequently asked questions

Does a refrigerator really draw more power when it starts?

Yes. The compressor motor needs a brief burst of extra current to overcome the refrigerant pressure and reach normal speed. As a rough rule of thumb, that spike can be 3 to 6 times the running watts for a fraction of a second. The spike is too short to show up as a noticeable increase on your electric bill.

Is a 1,000 W inverter enough for a refrigerator?

It depends on the fridge's running and surge watts and on what else is connected. For the 120 W example, a 1,000 W continuous rating covers the running load easily. The surge rating still has to cover the 360 W to 720 W starting spike, so confirm that number on the inverter's specification sheet before you buy or rely on it.

How can I tell if a power station can start my fridge?

Compare the power station's surge rating with the fridge's starting watts. If you do not know the starting watts, use 720 W for a 120 W fridge as a conservative target. Then run a test during a supervised period and watch for shutdowns or beeps when the compressor starts. A unit that shuts down at the first start needs a higher surge rating or a different backup plan.

Why does the starting spike matter more than the running watts for backup power?

The spike sets the peak demand your inverter or generator must meet at the moment the fridge starts. Running watts drive how long your battery lasts, while surge watts decide whether the equipment can start the fridge at all. Both numbers matter, but a unit that cannot handle the surge will not run the fridge even if it has plenty of stored energy.

#refrigerator#starting watts#running watts#inverter sizing#power outage

Numbers in this guide use the same formulas and EIA data as our calculators. Read our Editorial policy.