# How Much Does It Cost to Run Central Air Conditioning Per Month?

> Central AC costs about $107 a month for a 3-ton unit at the US average rate. See the worked math by unit size, SEER rating, daily hours, and your state.

Source: https://kwhtally.com/guides/how-much-does-it-cost-to-run-central-air-conditioning-per-month
Updated: 2026-11-24

A 3-ton central air conditioner with a SEER rating of 14 that runs 8 hours a day costs about $107 a month at the US average residential rate of 17.3 cents per kWh. Your own number depends on four inputs: unit size, efficiency rating, daily runtime, and your local electricity rate. The math below shows how each input changes the bill, so you can substitute your own values.

[[calc:appliance]]

## The formula

Two steps give you the power draw and the monthly cost.

1. **Power draw (kW)** = cooling capacity in BTU per hour ÷ SEER ÷ 1,000. One ton of cooling equals 12,000 BTU per hour, so a 3-ton unit is rated at 36,000 BTU per hour. SEER (Seasonal Energy Efficiency Ratio) measures cooling output per watt-hour of electricity, so dividing capacity by SEER gives an approximate electrical draw in watts.
2. **Monthly cost** = kW × hours per day × 30 days × rate per kWh.

This is a rule-of-thumb approximation. A real unit draws more on very hot afternoons and less on mild days, and the indoor blower fan adds some load on top of the compressor figure.

## Worked example: 3-ton unit, SEER 14

Assume the unit runs 8 hours a day for a 30-day month and your rate is 17.3 cents per kWh.

- Power draw: 36,000 ÷ 14 = 2,571 W, or 2.57 kW.
- Cost per hour: 2.57 kW × $0.173 = $0.44 per hour.
- Monthly hours: 8 × 30 = 240 hours.
- Monthly energy: 2.57 kW × 240 h = 617 kWh.
- Monthly cost: 617 kWh × $0.173 = $106.75, or about $107.

## How unit size changes the bill

Larger units have more cooling capacity and draw more power. The table holds efficiency at SEER 14, runtime at 8 hours a day, and the rate at 17.3 cents per kWh.

| Unit size | Capacity (BTU/h) | Draw at SEER 14 (kW) | Monthly kWh (8 h/day) | Monthly cost |
|---|---|---|---|---|
| 2-ton | 24,000 | 1.71 | 411 | $71 |
| 3-ton | 36,000 | 2.57 | 617 | $107 |
| 4-ton | 48,000 | 3.43 | 823 | $142 |

The 4-ton unit costs about twice as much as the 2-ton unit to run for the same hours, since its draw is exactly twice as large (3.43 ÷ 1.71 ≈ 2).

## How efficiency rating changes the bill

A higher SEER rating means the same cooling takes less electricity. Holding the 3-ton unit at 8 hours a day and 17.3 cents per kWh:

| SEER | Draw (kW) | Monthly kWh | Monthly cost |
|---|---|---|---|
| 10 | 3.60 | 864 | $149 |
| 14 | 2.57 | 617 | $107 |
| 18 | 2.00 | 480 | $83 |

Moving from SEER 10 to SEER 18 cuts the monthly cost by about $66 ($149 − $83) for this example. Your real savings depend on how many hours the unit runs, which the next section covers.

## How runtime and your state's rate change the bill

Runtime matters as much as unit size, because a summer cooling season can easily include many more hours of running on a hot day than on a mild one. The table below uses the 3-ton, SEER 14 unit and three rates from the EIA Electric Power Monthly, Table 5.6.A (November 2025, preliminary): the US average of 17.3 cents, North Dakota at 11.93 cents (lowest), and Hawaii at 40.2 cents (highest).

| Daily hours | Monthly kWh | US average (17.3¢) | North Dakota (11.93¢) | Hawaii (40.2¢) |
|---|---|---|---|---|
| 4 | 309 | $53 | $37 | $124 |
| 8 | 617 | $107 | $74 | $248 |
| 12 | 926 | $160 | $110 | $372 |

Two examples show the range. A 3-ton unit running 12 hours a day in Hawaii costs about $372 a month, while the same unit running 4 hours a day in North Dakota costs about $37. The same hardware can produce a monthly bill ten times higher depending on where you live and how hard the system works.

These figures assume a flat rate. Time-of-use plans charge more during peak afternoon hours, which is when many AC systems run hardest, so check your utility's rate structure. For your state's typical rate, see the [electricity rates by state](/electricity-rates-by-state) page, and for a broader view of why bills differ by region, read [Average Electric Bill by State in 2026: What Drives the Gap](/guides/average-electric-bill-by-state-in-2026-what-drives-the-gap).

## Calculate your own number

You need three values. Find the tonnage and SEER on the outdoor unit's nameplate or in your installation paperwork. Find your rate in cents per kWh on your electric bill, and divide your total charge by your kWh to check it. Estimate your daily running hours from your thermostat history, or from a few summer days of observation.

Then run the numbers through the [Appliance Energy Cost Calculator](/calculators/appliance-energy-cost-calculator). To see how the AC fits into your whole bill, use the [Electric Bill Calculator](/calculators/electric-bill-calculator).

## Ways to lower the monthly cost

The biggest levers follow directly from the formula. Cutting runtime reduces kWh in direct proportion, so a thermostat setting that avoids running the system at night or while the house is empty pays off every month. Keeping air filters clean and ductwork sealed helps the system deliver cooling without extra running time. When a unit is due for replacement, comparing SEER ratings with the table above shows what each step up in efficiency is worth at your runtime and rate.

Electrical work carries its own safety rules. A central AC needs a correctly sized dedicated breaker and wiring, so have a licensed electrician check the circuit before any upgrade or replacement.

## Frequently asked questions

### Why does my AC cost more on the hottest days?

On very hot days the outdoor temperature rises, and the system must work harder to move heat out of your home. Real power draw then exceeds the SEER-based estimate, which is an average figure. Expect your highest bills in the peak weeks of summer.

### Is the estimate the same as the extra charge on my bill?

No. The calculation covers only the cooling system's electricity use. Your bill also includes refrigerators, lighting, water heating, and everything else, and the extra AC charge is hard to isolate without a monitoring device.

### Does a higher SEER rating always save money?

A higher SEER rating uses less electricity for the same cooling, so savings grow with runtime and your rate. In the 3-ton example, moving from SEER 10 to SEER 18 saves about $66 a month at 8 hours a day. The purchase price of a higher-efficiency unit determines whether those savings pay back the difference, and that depends on your climate and local rates.

### What if my AC runs only part of the day?

The formula still works. Use your actual average daily hours in place of 8, and the monthly figure scales in proportion. For example, 4 hours a day cuts the 3-ton, SEER 14 cost at 17.3 cents from about $107 to about $53.